Audio/Demod Signal Rx Meter Remote Commands
5 - 9
5.5.8
AF Distortion - Upper Limit Value
:LIMits:AF:DISTortion:UPPer:VALue
:LIMits:AF:DISTortion:UPPer:VALue?
Description:
Set command defines the Upper Limit Value for AF Distortion measurement.
Query command returns parameter setting.
Range:
0.0 to 100.0%
Units:
% (percent)
Default Value:
5.0%
Set/Query Format:
NRf | NR2
Example:
:LIMits:AF:DISTortion:UPPer:VALue 1
Sets Upper Limit Value for AF Distortion measurement to 1.0%.
Query Response:
:LIMits:AF:DISTortion:UPPer:VALue?
1.00