Audio/Demod Signal Rx Meter Remote Commands
5 - 36
5.14
MODULATION DISTORTION MEASUREMENTS
5.14.1
Modulation Distortion - Averages
:CONFigure:MOD:ANALyzer:DISTortion:AVERage
:CONFigure:MOD:ANALyzer:DISTortion:AVERage?
5.14.2
Modulation Distortion - Average Measurement Reset
:MOD:ANALyzer:DISTortion:CLEAR:AVG
5.14.3
Modulation Distortion - Lower Limit Enable
:LIMits:MOD:DISTortion:LOWer:ENABle
:LIMits:MOD:DISTortion:LOWer:ENABle?
Description:
Set command defines number of readings taken to calculate Average
Modulation Distortion measurement.
Query command returns parameter setting.
Range:
1 to 250
Default Value:
1
Set/Query Format:
NR1
Example:
:CONFigure:MOD:ANALyzer:DISTortion:AVERage 75
Sets number of readings taken to calculate Average Modulation Distortion
measurement to 75.
Query Response:
:CONFigure:MOD:ANALyzer:DISTortion:AVERage?
75
Description:
Command clears and resets Average Modulation Distortion measurement.
Parameter/Query:
none
Description:
Set command Enables/Disables Lower Limit for Modulation Distortion
measurement.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:LIMits:MOD:DISTortion:LOWer:ENABle ON
Enables Lower Limit for Modulation Distortion measurement.
Query Response:
:LIMits:MOD:DISTortion:LOWer:ENABle?
1
Summary of Contents for 3900 Series
Page 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Page 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...