Audio/Demod Signal Rx Meter Remote Commands
5 - 13
5.7
AF HUM & NOISE MEASUREMENTS
5.7.1
AF Hum & Noise - Averages
:CONFigure:AF:ANALyzer:HN:AVERage
:CONFigure:AF:ANALyzer:HN:AVERage?
5.7.2
AF Hum & Noise - Average Measurement Reset
:AF:ANALyzer:HN:CLEAR:AVG
5.7.3
AF Hum & Noise - Lower Limit Enable
:LIMits:AF:HN:LOWer:ENABle
:LIMits:AF:HN:LOWer:ENABle?
Description:
Set command defines the number of readings taken to calculate Average AF
Hum & Noise measurement.
Query command returns parameter setting.
Range:
1 to 250
Default Value:
1
Set/Query Format:
NR1
Example:
:CONFigure:AF:ANALyzer:HN:AVERage 75
Sets number of readings being taken to calculate Average AF Hum & Noise
measurement to 75.
Query Response:
:CONFigure:AF:ANALyzer:HN:AVERage?
75
AF Analyzer Noise measurement type must be defined as Signal to Noise Ratio
(:AF:ANALyzer:NTYPe SN) and SNR measurement defined as Hum & Noise
(:CONFigure:AF:ANALyzer:SNR:MODE 0) to obtain valid Hum & Noise
measurement.
Description:
Command clears and resets Average AF Hum & Noise measurement.
Parameter/Query:
none
Description:
Set command Enables/Disables Lower Limit for AF Hum and Noise
measurement.
Query command returns parameter setting.
Parameter:
OFF | ON | 0 | 1
Default Value:
OFF
Set/Query Format:
Boolean
Example:
:LIMits:AF:HN:LOWer:ENABle ON
Enables Lower Limit for Hum & Noise measurement.
Query Response:
:LIMits:AF:HN:LOWer:ENABle?
1
AF Analyzer Noise measurement type must be defined as Signal to Noise Ratio
(:AF:ANALyzer:NTYPe SN) and SNR measurement defined as Hum & Noise
(:CONFigure:AF:ANALyzer:SNR:MODE 0) to obtain valid Hum & Noise
measurement.
N O T E
N O T E
Summary of Contents for 3900 Series
Page 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Page 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...