Generator/Transmit Channel Remote Commands
2 - 8
2.3.13
AF Generators - Tone Sequential Audio Level
:AF:GEN:TONE:SEQuential:MASTER:LEVel
:AF:GEN:TONE:SEQuential:MASTER:LEVel?
2.3.14
AF Generators - Tone Sequential Mode
:AF:GEN:TONE:SEQuential:MODE
:AF:GEN:TONE:SEQuential:MODE?
2.3.15
AF Generators - Tone Sequential Protocol
:AF:GEN:TONE:SEQuential:PROTocol
:AF:GEN:TONE:SEQuential:PROTocol?
Description:
Set command defines the Audio Level for Tone Sequential tones.
Query command returns parameter setting.
Range:
20.0 to 5000.0 mV
Units:
mV | V
Default Value:
1.0 V
Set/Query Format:
NRf | NR2 (mV)
Example:
:AF:GEN:TONE:SEQuential:MASTER:LEVel 2V
Sets the Audio Level for Tone Sequential tones to 2.0 Volts.
Query Response:
:AF:GEN:TONE:SEQuential:MASTER:LEVel?
2000.0
Description:
Set command selects Tone Mode of operation.
Query command returns parameter setting.
Parameter:
SINGLE | CONTINUOUS
Default Value:
SINGLE
Set/Query Format:
CPD | CRD
Example:
:AF:GEN:TONE:SEQuential:MODE CONTINUOUS
Sets Mode of Tone Sequential burst to Continuous.
Query Response:
:AF:GEN:TONE:SEQuential:MODE?
CONTINUOUS
Description:
Set command selects protocol of single tone.
Query command returns parameter setting.
Parameter:
ZVEI1 | ZVEI2 | ZVEI3 | PZVEI | DZVEI | PDZVEI | CCIR1 | CCIR2 | PCCIR |
EEA | EUROSIG | NATEL | EIA | MODAT
Default Value:
ZVEI1
Set/Query Format:
CPD | CRD
Example:
:AF:GEN:TONE:SEQuential:PROTocol PZVEI
Sets Protocol for tone to PZVEI.
Query Response:
:AF:GEN:TONE:SEQuential:PROTocol?
PZVEI
Summary of Contents for 3900 Series
Page 1: ...3900 Series Digital Radio Test Set dPMR Remote Programming Manual ...
Page 4: ...Preface ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 6: ...Contents iv THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 44: ...Generator Transmit Channel Remote Commands 2 34 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 69: ...Analyzer Receiver Remote Commands 3 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 147: ...Audio Demod Signal Rx Meter Remote Commands 5 54 THIS PAGE INTENTIONALLY LEFT BLANK ...