640
Vess
R2000
Series
Product
Manual
Promise
Technologies
Faulty Cable
To check for a faulty SAS cable:
1. Power down the RAID subsystem and JBOD units.
2. Replace the SAS cable with a new one.
3. Power up the subsystems and monitor the link port counter for changes in the rate of link error
accumulation.
Faulty Controller or I/O Module Connector
To check for a bad controller or I/O module SAS connector:
1. With the subsystems online and I/Os running, access the CLI via serial or Telnet.
See “Initial Connection” on page 206.
2. At the command prompt, type the following command and press
Enter
.
administrator@cli> sasdiag -a errorlog -l expander -e 1 -i 1
3. At the command prompt, type the following command and press
Enter
.
administrator@cli> sasdiag -a errorlog -l c2cport
By interpreting the two error logs, you can verify which controller or I/O module SAS port is accumulating link
errors.
Summary of Contents for R2000 SERIES
Page 1: ...ProductManual ...
Page 2: ...Vess R2000 Series Product Manual Version 2 0 2014 PROMISE Technology Inc All Rights Reserved ...
Page 83: ...Vess R2600i with SAS JBOD expansion 56 Vess R2000 Series Product Manual Promise Technologies ...
Page 151: ...124 Vess R2000 Series Product Manual Promise Technologies Topology display ...
Page 302: ...275 Product Manual NAS Function and Management Redundancy with port configuration ...
Page 704: ... 2014 PROMISE Technology Inc All Rights Reserved ...