319
Product Manual
-t <type>
Specifies what type of scheduler.
mp
Media Patrol Schedule.
rc
Redundancy Check Schedule.
br
Battery Reconditioning Schedule.
sc
Spare Drive Check Schedule.
-i <RC scheduler id>
Specifies the RC scheduler ID.
It’s used for list/modify/delete RC scheduler. If the option is not specified, assumed to all.
-s “<option>=<value>”
Used to specify which BGA scheduler settings to change.
status=
Specifies status type of scheduler.
enable
Enable a scheduler.
disable
Disable a scheduler. The default is disable.
starttime=
Used to specify start time of scheduler in the following format
hh:mm where hour’s range is 0-23, minute’s range are 0-59.
The default is 20:00 for MP, 22:00 for RC and SC, 02:00 for others.
recurtype=
Specifies recurrence type of scheduler.
daily
weekly
The default is weekly.
monthly
recurInterval=
Specifies recurrence Interval.
This option is for Daily and Weekly recurrence type.
For Daily type, the range is 1-255. (default is 1)
For Weekly type, the range is 1-52.
For Weekly type, the default is 4 for MP, 2 for RC,1 for others.
dow=
Day of Week. This is for Weekly or Monthly recurrence type
scheduler.
Examples
bga
bga -a mod -s “autorebuild=enable,rebuildrate=high,syncrate=low”
Summary of Contents for R2000 SERIES
Page 1: ...ProductManual ...
Page 2: ...Vess R2000 Series Product Manual Version 2 0 2014 PROMISE Technology Inc All Rights Reserved ...
Page 83: ...Vess R2600i with SAS JBOD expansion 56 Vess R2000 Series Product Manual Promise Technologies ...
Page 151: ...124 Vess R2000 Series Product Manual Promise Technologies Topology display ...
Page 302: ...275 Product Manual NAS Function and Management Redundancy with port configuration ...
Page 704: ... 2014 PROMISE Technology Inc All Rights Reserved ...