![Vess R2000 SERIES Product Manual Download Page 364](http://html.mh-extra.com/html/vess/r2000-series/r2000-series_product-manual_1008893364.webp)
337
Product Manual
ctrltempcritical=
(81 - 85) Controller temperature, displayed in Celsius, that the
controller will consider as a critical threshold.
-t <FRU type>
Used with action locate to indicate which type of FRU to locate. If
-t is not specified, it indicates to locate the enclosure.
ctrl
To locate controller.
cooling
To locate cooling unit. It only works with SAS type enclosure.
psu
To locate power supply unit. It only works with SAS type enclosure.
-f <FRU id>
Used with action locate and -t <FRU type> option to indicate which
FRU to locate. The valid values for FRU id are 1,2,3 and 4.
-v
Verbose mode. Used with -a list. VPD information will also be
displayed when using this switch.
Examples
enclosure
enclosure -v
enclosure -a mod -s “tempwarning=40,tempcritical=70”