Chapter 2 - Installation
_______________________________________________________________________________________________________________
MNL000530
Revision 1
03/15/2018
BSGS eV / BULKGUARD eV
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
2
-
33
SW2-8 Parity Switch setting:
- "On" if total number of active hardwire circuits is 0, 2, 4, 6, 8, 10, or 12.
- "Off" if total number of active hardwire circuits is 1, 3, 5, 7, 9, or 11.
Customer Board parity LED will be green when switches are configured correctly.
A digital-input that is in the OPEN state and configured as a hardwire will have the same functional
effect as pressing the EMO (Emergency Stop) switch.
Analog Inputs (Customer)
(AP1563 Customer I/O board)
Analog inputs supplied power at 24VDC fused @ 100 mA each w/ 100 Ω series resistor.
Analog Input #
Customer Brd
Signal
Customer Brd
24 VDC+
Customer Brd
GND
17
T1 - 5
T1 - 6
T1 - 4
18
T1 - 2
T1 - 3
T1 - 1
19
T2 - 5
T2 - 6
T2 - 4
20
T2 - 2
T2 - 3
T2 - 1
21
T3 - 5
T3 - 6
T3 - 4
22
T3 - 2
T3 - 3
T3 - 1