VTK-VS-BA-015e-A | User Manual MDS 3200+ Series
|
Cleaning
97
−
Place the tappet guidance onto tool MDT 303, with the pins of the latter inside the three
bores of the tappet guidance. Screw the tappet guidance into the nozzle adjustment nut.
To be able to screw the tappet guidance tight enough, use the tools MDT 301 and MDT
302, which will allow you to have a better grip
(see picture)
. Make sure to fix the tools
with your finger as shown. Otherwise you might screw lop-sided.
−
Screw the nozzle unit lightly onto the valve.
−
Use tool MDT 301 to screw the nozzle unit in. Do not screw till the end, but just for two
rotations.
Finally mount the cartridge holder, and connect the actuator and sensor cables as well as the
compressed air. More detailed information can be found in sections 5.2 and 5.3.2.