VTK-VS-BA-015e-A | User Manual MDS 3200+ Series
|
Error Messages
Error handling:
•
Interrupt data transmission.
•
Send data again.
Valve:
Valve remains unchanged
21
MDV 1Wire Error Press Enter
This error message appears, if an error occurs while writing the Cycle Counter.
Error code display:
MDV 1Wire Error Press Enter
Error code status menu:
No entry
Error handling:
•
Press
[enter]
key to acknowledge error message.
Valve:
Valve remains unchanged. If the error message appears during
the start of the MDC, the valve is open, otherwise it is closed.
22
Save Error Press Enter!
This error message appears, if an error occurs while writing the tappet or nozzle interval.
This can happen e.g. with the items “Set Nozzle“ or “Set Tappet“ in the submenu “Status“.
Error code display:
Save Error Press Enter!
Error code status menu:
Save Error
Error handling:
•
Press
[enter]
key to acknowledge error message.
Valve:
Valve is closed
23
RS Power Supply Press Enter
This error message appears, if a problem with the power supply forces a re-start of the sys-
tem. If this happens more than once, you need to change your dispensing parameters, since
your current settings use too much power over time.
Error code display:
RS Power Supply Press Enter
Error code status menu:
RS Power Supply
Error handling:
•
Press
[enter]
key to acknowledge error message.
•
Lower the dispensing frequency, since your current settings
need too much power.
Valve:
Valve still open
(start-up of the MDC)