VTK-VS-BA-015e-A | User Manual MDS 3200+ Series
|
Communication Interfaces
63
Return:
OK
21
SYSTEM:SHOW:CYCLES
Description:
The current value of the cycle counter is indicated.
Example:
Input:
SYSTEM:SHOW:CYCLES
Result:
Current value of the cycle counter.
Return:
1235000
22
SYSTEM:SHOW:VALVEID
Description:
The valve ID is displayed.
Example:
Input:
SYSTEM:SHOW:VALVEID
Result:
ID of the connected valve.
Return:
Valve ID: 11CW36
23
SYSTEM:SHOW:CONTROLLERID
Description:
The ID of the control unit is displayed.
Example:
Input:
SYSTEM:SHOW:CONTROLLERID
Result:
ID of the control unit.
Return:
Controller ID: 3050
24
SYSTEM:SHOW:AKTORTEMP
Description:
The current temperature of the actuator
(piezo)
is displayed.
Example:
Input:
SYSTEM:SHOW:AKTORTEMP
Result:
The value appears in °C.
Return:
80
25
SYSTEM:DOSOKAYDELAY:OFF
Description:
This command deactivates the DOSOK-Delay.
When this is true, the length of a delay is not added to the length of the
DOSOK signal.
Example:
Input:
SYSTEM:DOSOKDELAY:OFF
Result:
Deactivates the DOSOK-delay.
Return:
OK
26
SYSTEM:DOSOKAYDELAY:ON
Description:
This command activates the DOSOK-Delay.
When this is true, the length of a delay is added to the length of the DOSOK
signal.
Example:
Input:
SYSTEM:DOSOKDELAY:ON
Result:
Activates the DOSOK-delay.
Return:
OK