CORRECT CHANGE ONLY CONTROL CCOC (protected menu)
CORRECT CHANGE RULE
If in CCOC CON = 0 (means the VMC automatically manages the changer settings)
If changer is able to give the change back (CCU (correct change value) + Maximum Price)
correct change LED is OFF. Otherwise correct change LED is ON
If correct change LED is ON or OFF the VMC automatically accepts only coins than can
be returned or can return the equivalent credit with other coins.
ACC (Unconditional acceptance value) is automatically managed equal to the Maximum
price.
If in CCOC CON = 1 (means the VMC manages the changer setting according to
CONFY setting)
Correct change LED is set regarding the C2 (Low change equation) and C3 (minimum
coins Tube level).
If correct change LED is OFF VMC accept coins set in C06 and C07
If correct change LED is ON VMC accept coins set in C08 and C09
ACC (Unconditional acceptance value) is automatically managed equal to the Maximum
price.
If the ENTER button is activated at the "CCOC" prompt the VMC will show the actual
overpay status “"CONX" where X is:
0 = overpay not allowed or
1 = overpay allowed
Use up or down button to select the other submenu available (“CCU”, “ACC” and
“CONFY”), or press enter button to change X value.
“CCU” if you press enter at the “CCU” prompt, the display show the actual maximum
value used by VMC to work in correct change situation, you can change the
value using up or down button.
“ACC” if you press enter at the “ACC” prompt, the display show the actual maximum
value accepted, even if the VMC doesn’t know if it has the change, you can
change the value using up or down button (see CON>>>C9)