4 TEMPERATURE ADJUSTMENT
4.1 COOLING UNIT CONTROL SERETEC DSM 5030 USED UNTIL FEBRUARY 2010
The temperature adjustment can be done in a very simple and direct way through the
electronic control unit. Please proceed as follows:
To visualize the set temperature, press and release
key, the set temperature
appears on display with blinking mode for approx. 10 seconds.
If you wish to modify this value, while it is blinking, press
key to increase, or press
key to decrease it. Wait till the controller exits from the programming mode and return
to the operating mode (showing the internal temperature of the cell), which is registered
automatically.
The so-called set-point is the temperature, which makes the compressor stop, because it
reaches the ideal temperature to maintain the products loaded in the vending machine.
The compressor will re-start when it exceeds the set-point tempe parameter tDIF
(delta temperature).