Programming Manual
GLASSFRONT VENDING MACHINES
Rev. 1.12
MODELLS: G-DRINK SVE GF6 / GF9 – DR6 / DR9
Page 5 of 42
SPACE TO SALE FACILLITY
It is possible to group selections of the same product to one group.
•
Up to 10 Groups of 63 selections
•
Price per Group to avoid mistakes
•
Copy function for quick setting
DOOR SWITCHES
For security purpose 2 Door switches are included in the machine, 1 for the slave lift
control board and cooling unit and 1 to main board. If one of the door switches is not in
closed position nothing in the lift side is allowed to move. Also the cooling unit is stopped.
VEND CONDITIONS MODE
Conditions are:
-
Doors switches are closed
-
Delivery flap is closed
-
Drum is in closed position with not product inside and no errors reported
-
Initialisation of the slave memory and shelves report has been properly done
-
No error in the lift and bucket are reported (see Lift error list). If an error is
continuosly reported by the slave controller, any movement or initialisation will be
performed by the master until no error is reported. (see ERROR ROUTINE)
-
MDB communication is working correctly
VEND DETECTION PROCESS
The product is detected when crossing the delivey inner flap by a magnetic sensor which
have the contact open when the door is open for more than 15mm.
This detection will cause the vend price deduction from the established credit, if not the
selection will be in soldout and the credit can be returned or an other selection is possible.
As the product drop in the drum, another infrared sensor will detect the product and opens
the drum. As soon as the product is removed the light will flash and the drum is closing.
IF THE PRODUCT IS NOT DETECTED IN THE DRUM, BUT SEEN CROSSING THE
DELIVERY INNER FLAP DOOR GATE, THE DRUM IS OPENING AND STAYS OPEN
FOR A FIXED TIME (INDEPENDANTLY IF THE PRODUCT IS REMOVED). IF THE
PRODUCT IS DETECTED WHILE THE DRUM IS TURNING OR DURING THE
PRODUCT IS REMOVED THE PREVIOUS MODE FUNCTION IS CANCELLED AND
TIMER IS RESET.
TO IMPROVE THE DETECTION LEVEL, ON THE TOP OF THE INFRARED SENSOR
PUSH THE BUTTON FOR 1 SECOND AND RELEASE IT WHEN THE LED IS BLINKING
QUICKLY IN THAT WAY THE MAXIMUM THRESHOLD IS SET TO THE MAXIMUM.