3 DRUM SENSOR ADJUSTMENT
If the product is not detected in the drum, but seems to be detected by the delivery flap
sensor, the drum will open for a fixed time (independent whether the product is removed).
If the product is detected while the drum is turning or the product is removed, the previous
mode function is cancelled and the timer is reset.
Instruction for adjusting the photocell:
1. Insert the adjusting key “A”, supplied with the photocell, in the cut "B" on the front side.
2. Turn the adjusting key until led “C” positioned on the lower side of the photocell is on.
3. Turn the adjusting key in the opposite direction until the led is off.
4. Turn in the opposite direction and stop the adjustment immediately after the led is on.
5. Check the change of the led from on (product not present) to off (product present) by
passing an object between the photocell and the reflector.
B
C
A