2.1 ERROR ROUTINE
If the ENTER button is activated at the "ERROR" prompt the VMC will enter in the error
routine. If no errors have occurred since the last error reset the display will show a
"NONE" message. If an error has been detected since the last error reset the display will
show the first summary level error code that has occurred, such as "LIFT", which would
indicate a lift jam error. Using the UP or DOWN buttons will cycle through the various
summary level error. On the appendix A (Map of internal menu) you find all the error that
the machine can generate.
Activation of the HOME button while summary level error code is displayed will return the
VMC to the "ERROR" prompt.
Activation of the HOME button at "ERROR" prompt returns the VMC to the normal mode
door open state.
LIFT ERROR ROUTINE
If the ENTER button is activated at the "LIFT" prompt the VMC will display a "ERRxx"
message where XX indicates the kind of error that have been detected as being jammed.
Using the UP and DOWN buttons will cycle through all jammed columns. If the ENTER
button is pressed and held for two seconds during the display of any error code, that code
will be cleared.
After clearing, VMC will display the next existing column jam error, or "NONE" if no other
error.
Activation of HOME button will return the VMC to the code level at the "ERROR" message.
LIFT ERROR LIST
ERR01 Jamming or speed error on the Y vertical motor
ERR02 Home switch Y not found or connected
ERR03 Optical Y sensor doesn’t found shelves position
ERR04 Jamming or speed error on the X horizontal motor
ERR05 Home switch X not found or connected
ERR06 Optical X sensor doesn’t found columns position
ERR07 Slave unit error or initialisation missing
ERR08 Slave unit Memory error or initialisation corrupted
ERR09 Vend error
ERR10 Initialisation error or wrong shelves setting
ERR11 Bucket jammimg or missing signal
ERR12 Lock error ,missing contact on the slave board
ERR13 Slave door switch contact missing
ERR14 Hopper switch error contact missing
ERR15 Slave error power supply 24Vdc
ERR16 Delivery Flap door remaining open or switch missing
ERR17 Wrong shelves number detected
These potential errors will be automatically cleared at the door closing, then a new
initialisation will be performed to check if the failure (error) is remaining.