27 / 43
ALARMS
ALARM NUMBER
1
SEQUENCE(SECS)
1
ALARM ACT
CRUISE
ACTIVATE AUX
OFF
<CLEAR SET>
DWELL TIME<SECS>1
0
DWELL TIME<SECS>2
0
BACK
EXIT
Screen 19: Alarms Sub-Menu
The camera has 4 alarm inputs and 2 alarm outputs. The actions defined by the user may be associated to an alarm.
Option
Value
Explanation
ALARM NUMBER
1 ~ 4
This option allows selecting one of the 4 alarm inputs.
SEQUENCE (SECS)
1 ~ 250
Duration time (in seconds) of the action related to each alarm
when several alarms occur at the same time.
ALARM ACT
NONE
No action is performed on alarm.
AUTO SCAN
The camera performs an auto scan on alarm: the camera
performs a 360 horizontal scan operation.
RANDOM SCAN
The camera performs a random scan on alarm: the camera
performs a random 360° scan pausing for approximately 2
” every
142°.
FRAME SCAN
The camera performs a frame scan on alarm: the horizontal scan
is performed in the SET SCAN limits.
PRESET
The camera goes to related preset on alarm.
PATTERN 1
The camera performs pattern action 1 on alarm.
PATTERN 2
The camera performs pattern action 2 on alarm.
PATTERN 3
The camera performs pattern action 3 on alarm.
PATTERN 4
The camera performs pattern action 4 on alarm.
CRUISE
The camera performs a cruise on alarm: the camera runs a cycle
consisting of up to 30 preset positions.
TRACKING
The camera performs tracking action on alarm.
PRESET N TRA
The camera goes to related preset and starts tracking function.
CRUISE TRA
The camera performs a cruise with tracking on alarm.
ACTIVATE AUX
OFF
No action occurs after the alarm.
1
Output 1 is on.
2
Output 2 is on.
CLEAR SETTINGS
This submenu is used to delete the alarm programming (see
below).
DWELL TIME<SECS>1
0 ~ 255
The duration of related alarm output
DWELL TIME<SECS>2
0 ~ 255
The duration of related alarm output
Table 15
If an alarm is triggered during any automatic operation of the camera (Pattern, Auto Tracking, etc.), the operation
in progress is stopped and the camera executes the action that has been set in the
ALARM ACT
menu:
In the event of Preset action, the camera moves to the preset position. Then, if the option
PARK ACTION
is
set to execute an action, the action will be executed after the
PARK TIME
period has expired.
In the event of "
PATTERN, AUTO SCAN, RANDOM SCAN, FRAME SCAN, CRUISE
" actions, the action is
executed by the camera permanently and can only be stopped by one of the following actions: any
command sent by a controller or any alarm event.
4.5.4.2.
ADDR SETTING