2. C01-Malfunction Diagnosis Monitor Group
Function
code
Function name
Unit and definition
Addres
s
C01.00
Malfunction types
See fault code table
0x2200
C01.01
Malfunction diagnosis information
See fault code table
0x2201
C01.02
Malfunction running frequency
0.00
~
Max frequency
0x2202
C01.03
Malfunction output Voltage
0
~
1500V
0x2203
C01.04
Malfunction out Current
0.1
~
1000.0A
0x2204
C01.05
Malfunction Bus Voltage
0
~
3000V
0x2205
C01.06
Malfunction module temperature
0
~
100
℃
0x2206
C01.07
Malfunction machine state
LED “0” digit: Running direction
0: FWD 1: REV
LED “00” digit: Running status
0: Stop 1: ACC
2: DEC 3:Constant speed
LED “000” digit: Reserved
LED “0000” digit: Reserved
0x2207
C01.08
Malfunction input terminal status
See input terminal chart
0x2208
C01.09
Malfunction output terminal status
See output terminal chart
0x2209
C01.10
The last malfunction types
Please see malfunction code table
0x220A
C01.11
The first diagnosis information
Please see malfunction code table
0x220B
C01.12
The last malfunction running frequency
0.00~Maxfrequecy
0x220C
C01.13
The last malfunction output voltage
0
~
1500V
0x220D
C01.14
The last malfunction output current
0.1
~
2000.0A
0x220E
C01.15
The last malfunction bus voltage
0
~
3000V
0x220F
C01.16
The
last malfunction module
0
~
100
℃
0x2210
C01.17
The last malfunction machine state
LED “0” digit: Running direction
0: FWD
1: REV
LED “00” digit: Running status
0: Stop
1: Constant speed
2: ACC
3: DEC
LED “000” digit: Reserved
LED “0000” digit: Reserved
0x2211
C01.18
The last malfunction input terminal
See input terminal chart
0x2212
C01.19
The last malfunction output terminal
See output terminal chart
0x2213
C01.20
The first two malfunction types
Please see malfunction information code
table
0x2214
C01.21
The first two diagnosis information
0x2215
C01.22
The first three malfunction types
0x2216
C01.23
The first three diagnosis information
0x2217
AC300 Series Vector Control Inverter Manual
AC300 IO Expansion Card Manual
177
Appendix 1: AC300 IO Expansion Card Manual
1. AC300IO Expansion Card Introduction
The AC300 inverter has a powerful expansion functions. The AC300IO1 expansion card is a terminal expansion card
that can be used in our AC300 full range of inverters. Enriched the input and output terminal functions of the inverter
can meet the needs of various applications in specific situations.
2. AC300IO Card Ordering Model
Product order model: AC300IO1
3. AC300IO Expansion Card Instructions
Product technical parameters
Category
Digital input signal characteristics
Signal name
Response frequency range
input resistance
Effective level range
Input
signal
X6,X7,X8,X9
0-50KHz
About 4.4 K
Ω
High level
:
10V~-30V
X10
0-50KHz
About 1.5 K
Ω
Low level
:
0V~-8V
Category
Digital output signal characteristics
Signal name
output method
Maximum output
Output
signal
Y2
NPN collective tube open collector output
DC24V/50mA
TA2,TB2,TC2
Relay normally open normally closed output
3A/240VAC
Category
PT100 thermocouple analog input signal characteristics
Signal name
output method
Detection temperature range
PT100 Signal
PK+/PK-
Differential two-wire input
0
℃
-200
℃
Terminal Function Introduction