AC300 Series Vector Control Inverter Manual
Function Parameter Table
156
F03.03
AI1 upper limit
corresponding setting
-100.00
~
100.00%
100.00
%
●
0x303
F03.04
AI1 filter time
0.000
~
6.000s
0.010s
●
0x304
F03.05
AI1 zero point loop
0.00
~
10.00V
0.00V
●
0x305
F03.06
AI2 Lower limit
0.00
~
10.00V
0.00V
●
0x306
F03.07
AI2 Lower limit
corresponding setting
0.00
~
100.00%
0.00%
●
0x307
F03.08
AI2 upper limit
0.00
~
10.00V
10.00V
●
0x308
F03.09
AI2 upper limit
corresponding setting
0.00
~
100.00%
100.00
%
●
0x309
F03.10
AI2 filter time
0.000
~
6.000s
0.010s
●
0x30A
F03.11
AI2 zero point loop
0.00
~
10.00V
0.00V
●
0x30B
F03.12
AI1 function selection
See X terminal function
0
〇
0x30C
F03.13
AI1 high level setting
0.00
~
100.00%
70.00%
●
0x30D
F03.14
AI1 low level setting
0.00
~
100.00%
30.00%
●
0x30E
F03.15
AI2 function selection
See X terminal function
0
〇
0x30F
F03.16
AI2 high level setting
0.00
~
100.00%
70.00%
●
0x310
F03.17
AI2 low level setting
0.00
~
100.00%
30.00%
●
0x311
F03.18
Valid state setting
when analog used as
terminal
0: low level 1: high level
LED “0” digit: AI1
LED “00” digit: AI2
LED “000” digit: reserved
LED “0000” digit: reserved
0000
●
0x312
F03.19
Analog input curve
selection
LED “0” digit: AI1
0: Beeline (default) 1: curve 1 2:
curve 2
LED “00” digit: AI2 (Select voltage or
current input by wire jumper)
LED “000” digit: reserved
LED “0000”digit: reserved
0000
●
0x313
F03.20
Reserved
0x314
F03.21
Curve 1 lower limit
0.00
~
10.00V
0.00V
●
0x315
F03.22
Curve 1 lower limit
corresponding setting
0.00
~
100.00%
0.0%
●
0x316
F03.23
Curve 1 inflection
point 1 input voltage
0.00
~
10.00V
3.00V
●
0x317
F03.24
Curve 1 inflection
point 1 corresponding
0.00
~
100.00%
30.00%
●
0x318
F03.25
Curve 1 inflection
point 2 input voltage
0.00
~
10.00V
6.00V
●
0x319
F03.26
Curve 1 inflection
point 2 corresponding
0.00
~
100.00%
60.00%
●
0x31A
F03.27
Curve 1 upper limit
0.00
~
10.00V
10.0V
●
0x31B
F03.28
Curve 1 upper limit
corresponding setting
0.00
~
100.00%
100.00
%
●
0x31C
AC300 Series Vector Control Inverter Manual
Function Parameter Table
157
F03.29
Curve 2 lower limit
0.00
~
10.00V
0.00V
●
0x31D
F03.30
Curve 2 lower limit
corresponding setting
0.00
~
100.00%
0.00%
●
0x31E
F03.31
Curve 2 inflection
point 1 input voltage
0.00
~
10.00V
3.00V
●
0x31F
F03.32
Curve 2 inflection
point 1 corresponding
0.00
~
100.00%
30.00%
●
0x320
F03.33
Curve 2 inflection
point 2 input voltage
0.00
~
10.00V
6.00V
●
0x321
F03.34
Curve 2 inflection
point 2 corresponding
0.00
~
100.00%
60.00%
●
0x322
F03.35
Curve 2 upper limit
0.00
~
10.00V
10.00V
●
0x323
F03.36
Curve 2 upper limit
corresponding setting
0.00
~
100.00%
100.00
%
●
0x324
F03.37
A0 output signal
selection
LED “0” digit: AO1
0: 0
~
10V
1: 4.00
~
20.00mA
2: 0.00
~
20.00mA
3: FM frequency pulse output
LED “00” digit: A02 extended card
0: 0
~
10V
1: 4.00
~
20.00mA
2: 0.00
~
20.00mA
LED “000” digit: reserved
LED 0000 digit: reserved
0000
●
0x325
F03.38
A01 output selection
0:Given frequency
1:Output frequency
2:Output current
3:Input voltage
4:Output voltage
5:Machine speed
6:Given torque
7:Output torque
8:PID given value
9:PID feedback value 10:Output power
11:Bus voltage
12:AI1
13:AI2
14:Reserved
15:PUL
16,17:IGBT temperature 1,2
18:RS485 given
0
●
0x326
F03.39
A02 extended output
selection
1
●
0x327
F03.40
A01 output gain
25.0
~
200.0%
100.0%
●
0x328
F03.41
A01 analog output
signal bias
-10.0%
~
10.0%
0.0%
●
0x329
F03.42
A01 output filter
0.000
~
6.000s
0.010s
●
0x32A