AC300 Series Vector Control Inverter Manual
Installation and Wiring
24
AC300-T3-5R5G 25A 20A ------ NFI-020
NFO-020
AC300-T3-7R5G 25A 30A ------ NFI-020
NFO-020
AC300-T3-011G 32A 40A ------ NFI-036
NFO-036
AC300-T3-015G 40A 50A ------ NFI-036
NFO-036
AC300-T3-018G 50A 60A ------ NFI-050
NFO-050
AC300-T3-022G 50A 75A ------ NFI-050
NFO-050
AC300-T3-030G 63A 100A DCL-80
NFI-080
NFO-080
AC300-T3-037G 80A 125A
DCL-100
NFI-100
NFO-100
AC300-T3-045G 100A 150A DCL-110
NFI-100
NFO-100
AC300-T3-055G 125A 175A DCL-125
NFI-150
NFO-150
AC300-T3-075G 160A 200A DCL-150
NFI-150
NFO-150
AC300-T3-090G 220A 250A DCL-200
NFI-200
NFO-300
AC300-T3-110G 220A 300A DCL-200
NFI-200
NFO-300
AC300-T3-132G 250A 400A DCL-300
NFI-300
NFO-300
AC300-T3-160G 300A 500A DCL-300
NFI-300
NFO-300
AC300-T3-185G 400A 600A DCL-400
NFI-400
NFO-400
AC300-T3-200G 400A 700A DCL-400
NFI-400
NFO-400
AC300-T3-220G 630A 800A DCL-500
NFI-600
NFO-600
AC300-T3-250G 630A 1000A
DCL-600
NFI-600
NFO-600
AC300-T3-280G 630A 1200A
DCL-600
NFI-600
NFO-600
AC300-T3-315G 630A 1200A
DCL-800 ------ ------
AC300-T3-355G 800A 1400A
DCL-800 ------ ------
AC300-T3-400G 1000A 1600A
DCL-1000
------ ------
AC300-T3-450G 1000A 2000A
DCL-1000
------ ------
AC300-T3-500G 1000A 2000A
DCL-1200
------ ------
AC300-T3-560G ------ 2000A
DCL-1200
------ ------
Note: For DC reactor, input filter, output filter and other components specification details and circuit mode, please
refer chapter 7 “peripheral equipments and options”
AC300 Series Vector Control Inverter Manual
Installation and Wiring
25
Control loop terminals
●
Control loop terminals array
Table 3-7:AC300 series inverter control loop terminals array and definition
Sort
Terminal
Name
Function definition
Power
supply
+10V-GND
Ex10V power supply
P10V power supply to the outside,
the maximum output current: 50 mA is
generally used as external potentiometer
working power supply, potentiometer
resistance range: 1K
Ω
~ 5K
Ω
+24V-COM
Ex24V power supply
Pr24V power supply to the
outside, generally used as digital input
and output terminal working power supply
and external sensor power supply
Maximum output current: 100 mA
PLC
External
common terminal
Factory default connection with +24V
When using X1~X5/PUL to drive the
external signal, the PLC needs to be
connected to the external power supply
and disconnected from the +24V power
supply (see "+24V", "PLC", "COM"
connection diagram for details)
Analog input
AI1-GND
Voltage or current type analog input
1. Input current range: DC 0V ~ 10V / 0mA
~ 20mA
2. Voltage type input impedance: 100K
Ω
3. Current input impedance: 500
Ω
AI2-GND
Voltage or current type analog input
1. Input current range: DC 0V ~ 10V / 0mA
~ 20mA
2. Voltage type input impedance: 100K
Ω
3. Current input impedance: 500
Ω
Digital input
X1-PLC
Multi-function contact input 1
Optocoupler isolation, compatible with