Installation
LFXG-H Installation and Operation Guide
31
Mounting the measuring assembly
Mounting options:
• Bracket mount
The L-bracket supports the electronics housing. For this type of
mounting, the conduit clamps should be spaced every 18" (45cm).
• Conduit mount
This type of mount consists of an adapter with a 2" conduit coupler (part
number 240721). It provides an air hose fitting for applications that
must cool the gauge. The pole mount requires a nipple and union.
Note:
The detector’s active area (where it is possible to make a level
measurement) is between 1" (25mm) from the bottom of the
GEN2000 housing to the end of the flexible conduit. Mount the
detector so this area spans the measurement length.
Note:
In some cases, the handle on the source holder operates a
rotating shutter. When installing or removing the assembly from
the pipe, you must turn the handle to the closed (OFF) position
and lock the handle with the combination lock provided.