2.2.4.2 CLIPoA Setup
11:50:50
>LINK UP
4W STU-R<
PING SETUP
MODE
:
CLIPoA
ENCAPSULATION :LLC
VPI
:8
VCI
:35
IP ADDRESS
:207.181.199.176
LOCAL IP
:207.181.199.178
LLC-RTE CLIPoA
START
more
Figure 9 CLIPoA Configuration Screen
Configure theses settings for Classical IP over ATM:
ENCAPSULATION
Options: LLC
LLC is the only encapsulation method available.
VPI
Range: 1 to 255
The default is 8, which is a typical Ethernet assignment. Along
with VCI, VPI identifies the next destination of a cell as it moves
through a series of ATM switches on the way to its destination.
The service provider typically assigns VPI.
VCI
Range: 1 to 65535
The default is 35, which is a typical Ethernet assignment. Along
with VPI, VCI identifies the next destination of a cell as it moves
through a series of ATM switches on the way to its destination.
The service provider typically assigns VCI.
LOCAL IP
Enter the Local IP address of the circuit to be tested.
DESTINATION IP
Enter the Destination IP address to be pinged.
MTT-14B e_Manual D07-00-083P RevA00