08:39:57
>LINK UP
4W STU-R<
ALARM STATUS
LOCAL
REMOTE
curr hist curr
hist
CH1 -
SNR : NO NO NO NO
LOSW: NO NO NO NO
ATTN: NO NO NO NO
CH2 -
SNR : NO NO NO NO
LOSW: NO NO NO NO
ATTN: NO NO NO NO
STORE
2.2.2 Alarm Status
This screen provides
general alarm status
(current and history for
local and remote).
Note CH2 is reported
only in 4-wire mode.
Figure 6 Alarm Status Screen
This screen reports the following:
SNR
: Triggered when the local current SNR margin value is below
the user threshold setting. This is set in MODEM CONTROL >
SYSTEM SETTINGS, on the SNR MARGIN THRESHOLD line.
LOSW
: Loss of Sync defect alarm, a loss of synchronization word
defect is declared when at least 3 consecutive received frames
contain 1 or more errors. An LOSW defect is cleared when at
least 2 consecutive received frames contain no errors.
ATTN
: Triggered when the local attenuation value is greater than
the user threshold value. This is set in MODEM CONTROL >
SYSTEM SETTINGS, on the LOOP ATTN THRESHOLD line.
These alarm conditions are displayed as current and history.
These are defined as:
curr YES
: The alarm condition is currently detected.
curr NO
: The alarm condition is not currently detected.
hist YES
: The alarm condition has been detected, but it is no
longer present.
hist NO
: The alarm condition has never been detected since the
start of the test or since pressing HISTORY.
The following F-keys are available:
(F3): Send the alarm screen to the serial port.
STORE
(F4): Press to store the status screen
.
MTT-14B e_Manual D07-00-083P RevA00
Page 12 of 101