Use
VPI
VCI
Unassigned cell
00000000
00000000 00000000
Invalid
Any value other than 0
00000000 00000000
Meta-signaling
XXXXXXXX
00000000 00000001
General broadcast
XXXXXXXX
00000000 00000010
Point-to-Point signal-
ing
XXXXXXXX
00000000 00000101
Segment OAM F4 cell
Any value
00000000 00000011
End-to-end OAM F4
cell
Any value
00000000 00000100
VP resource manage-
ment
Any value
00000000 00000110
Reserved for future VP
functions
Any value
00000000 00000111
Reserved for future
functions
Any value
00000000 000SSSSS
1
Reserved for future
functions
Any value
00000000 000TTTTT
2
Segment OAM F5 cell
Any value
Any value other than
00000000 00000000,
00000000 00000011,
00000000 00000110,
00000000 00000111
End-to-end OAM F5
cell
Any value
Any value other than
00000000 00000000,
00000000 00000011,
00000000 00000100,
00000000 00000110,
00000000 00000111
Notes
1
any value from 01000 to 01111
2
any value from 10000 to 11111
Table 1 UNI VPI and VCI Values
MTT-14B e_Manual D07-00-083P RevA00