VDH Products BV
Document 063319 - version 3.12
Page:
57 of 78
Number
Description
Range
Value
Default
2160
2161
2162
2163
2164
2165
2166
2170
2171
CO2 sensor current at 0 ppm
CO2 sensor current at 500 ppm
CO2 sensor current at 1000 ppm
CO2 sensor current at 1500 ppm
CO2 sensor current at 2000 ppm
CO2 sensor current at 2500 ppm
CO2 sensor current at 3000 ppm
Pressure at 4mA
Pressure at 20mA
0.1..30.0
0.1..30.0
0.1..30.0
0.1..30.0
0.1..30.0
0.1..30.0
0.1..30.0
-125..125
-125..125
mA
mA
mA
mA
mA
mA
mA
-
-
4.0
6.7
9.3
12.0
14.7
17.3
20.0
0
150
3000
Digital Output Settings
3010
3020
3030
3040
3050
3060
3070
3080
3090
3100
3110
3120
3130
3140
3150
3160
3170
3180
3190
3200
3210
3220
3230
3240
3250
3260
Relay cooling 1
Relay cooling 2
Relay cooling 3
Relay heating 1
Relay heating 2
Relay heating 3
Relay gassing
Relay door lock
Relay fan 1
Relay fan 2
Relay fan 3
Relay fan 4
Relay fan general
Reserved, do not change!
Reserved, do not change!
Relay ventilation
Relay ventilation valve
Relay humidifier
Relay extra cooling
Relay fan failure
Relay airbag failure
Relay gas time exceeded
Relay absolute temperature alarm
Relay relative temperature alarm
Relay fan turn function
Relay cooling/heating active
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
-
-
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
0..20
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5
6
7
8
9
10
14
3
11
12
13
0
0
-
-
15
0
16
0
0
0
0
0
0
0
0
Summary of Contents for PROBA
Page 73: ...VDH Products BV Document 063319 version 3 12 Page 73 of 78...
Page 75: ...VDH Products BV Document 063319 version 3 12 Page 75 of 78...
Page 76: ...VDH Products BV Document 063319 version 3 12 Page 76 of 78...
Page 77: ...VDH Products BV Document 063319 version 3 12 Page 77 of 78 Jumper settings...