VDH Products BV
Document 063319 - version 3.12
Page:
51 of 78
Number
Description
Range
Value
Default
1300
Fan Settings
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1330
1331
1332
1333
1334
1335
1340
1341
1342
1343
1345
1346
1347
1348
1350
1351
1352
1370
1371
1372
1373
1374
Fan off when door open
Fan off delay when door open
Fan on delay when door closed
Fan only on if airbag is full
Fan on separately
Fan delay when switched on
separately
Fan off at minimum absolute alarm 1
Fan off at maximum absolute alarm 1
Fan off at minimum absolute alarm 2
Fan off at maximum absolute alarm 2
Fan off at failure airbag
Fan off at failure cooling
Fan off at failure heating
Fan 1 zone setting
0 = no zone = not present
1 = zone 1
2 = zone 2
3 = zone 3
Fan 2 zone setting
Fan 3 zone setting
Fan 4 zone setting
Turn rotating direction fan
Fan direction interval
When more fans in one zone, the
zone is switched off when one of
the fans is at failure
During fan failure, fans will
continue
Fans can be switched on/off from
front (if 1101=1)
Use pressure control fans
Minimum pressure setpoint
Maximum pressure setpoint
Parameters 1333..1352 are applicable for an
analog output assigned to combined pressure
and temperature based PID fan control, see
parameters 6001..6004)
P band pressure control
I time pressure control
d action pressure control
Parameters 1340..1343 are applicable when
cooling (see Figure 2)
offset setpoint for temperature fan control
P band temperature fan control
I time temperature fan control
delay (min) temperature fan control
Parameters 1345..1346 are applicable when
heating (see Figure 3)
offset setpoint for temperature fan control
P band temperature fan control
I time temperature fan control
delay (min) temperature fan control
Apply delay
Lower apply limit
Upper apply limit
Parameters 1370..1374 are applicable for an
analog output assigned to alternative
pressure fan control, see parameters
6001..6004)
Temperature dead band
P band pressure based control
Transition band
Freeze pressure based control outside
temperature dead band
I time pressure based control
0..1
0..999
0..999
0..1
0..1
0..60
0..1
0..1
0..1
0..1
0..1
0..1
0..1
0..3
0..3
0..3
0..3
0..1
1..24
0..1
0..1
0..1
0..1
0..125
0..125
0..50
1..999
0..999
0.0..20.0
0.0..20.0
1..999
0..60
-20.0..0.0
0.0..20.0
1..999
0..60
1..120
0..255
0..255
0.0..20.0
0..50
0.0..20.0
0..1
1..999
-
sec
sec
-
-
sec
-
-
-
-
-
-
-
-
-
-
-
-
hrs.
-
-
-
-
Pa
Pa
Pa
min
-
°C
°C
min
min
°C
°C
min
min
min
-
-
°C
Pa
°C
-
min
0
0
0
0
1
10
0
0
0
0
1
1
1
1
2
3
0
0
12
1
0
0
0 (1)
0
0 (125)
0 (10)
0
0
0.0 (2.0)
0.0 (5.0)
0 (999)
0
0.0 (-2.0)
0.0 (5.0)
0 (999)
0
0 (30)
0 (10)
0 (50)
0.0 (2.0)
0 (10)
0.0 (2.0)
0
0 (999)
Summary of Contents for PROBA
Page 73: ...VDH Products BV Document 063319 version 3 12 Page 73 of 78...
Page 75: ...VDH Products BV Document 063319 version 3 12 Page 75 of 78...
Page 76: ...VDH Products BV Document 063319 version 3 12 Page 76 of 78...
Page 77: ...VDH Products BV Document 063319 version 3 12 Page 77 of 78 Jumper settings...