Description
Required tool
6. Remove mechanical unit and clean
shaft.
Se
al
remova
l an
d
val
ve cle
an
in
g
7. Remove o-rings.
8. Clean shaft feedthrough and valve
body.
Lint and dust
free cloth
soaked with
isopropyl
alcohol
Lu
bri
cate
an
d in
stall
sea
ls
9. Lubricate seal contact surface of
valve body with a slight film of
vacuum grease (0.025 ml).
10. Lubricate each o-ring with a slight film
of vacuum grease (0.0125 ml).
Vacuum grease
11. Lubricate seal contact surface of
shaft with a slight film of vacuum
grease (0.0125 ml).
12. Slide both o-rings onto shaft till the
end.
13. Deposit 0.0375 ml vacuum grease
between the o-rings
14. Clean shaft from vacuum grease.
Vacuum grease