2.6.3 Power and sensor connection (+24 VDC sensors)
[612 . . - . .
G
. - . . . . / 612 . . - . .
H
. - . . . . versions recommended]
2.6.3.1
Sensor power wiring via controller
Note:
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away from noise sources.
Connect the +24 VDC sensors at DB
–15 female sensor connector exactly as shown in the drawing above. Do not
connect other pins, that may damage power supply or controller!
Connector: Use only screws with 4-40UNC thread for fastening the connectors!
Pins 4 and 8 must be bridged for operation!
An optional switch would allow for motor
interlock to prevent valve from moving.