2.6.2 Sensor supply concepts
This valve offers 2 alternative concepts to supply the sensor(s) with power. This depends on the sensor type that is used.
Optional is this valve available with an sensor power supply module (SPS) that converts 15 VDC from the 24 VDC.
Concepts:
Ex 24 VDC supplied to POWER connector is feed through to SENSOR connector to supply 24 VDC
sensors. Refer to chapter «Power and sensor connection (+24 VDC sensors)» for schematic and correct wiring.
External 15 VDC supplied to POWER connector is feed through to SENSOR connector to supply 15 VDC
sensors. Refer to chapter «Power and sensor connection ( 15 VDC sensors) without optional SPS module» for
schematic and correct wiring.
Valve versions:
612 . . - . .
G
. - . . . . and 612 . . - . .
H
. - . . . .
SPS module not included
Note:
The SPS module can be retrofitted. Refer to chapter «Retrofit / replacement procedure» for instruction.