Installation, Operating & Maintenance Instructions
Series 612 DN 250 (I.D. 10”), EtherCAT
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
282408EB
2012-04-23
63/81
3.16 PRESSURE and SENSOR READING allocation
Example of PRESSURE and SENSOR READING allocation:
Above picture shows a 2 sensor system. In this configuration sensor 2 covers low range (100 mTorr) and sensor 1
covers high range (1 Torr).
Switchover between sensors is done automatically according to «Pressure control operation with 2 sensors».
0
-10V
High range
sensor
Low range
sensor
0
-10V
SENSOR 1
100 mTorr
1 Torr
0 mTorr
SENSOR 2
PRESSURE
0
– 1’000'000