EXTENDED WARNING bitmap table:
Bit
Description
0
REMOTE CONTROL NOT
POSSIBLE
Remote control not possible, access mode local is active, change to acces mode remote or
access mode locked
1
ACTUAL CONTROL
MODE SETPOINT NOT
ALLOWED
Not possible to switch the actual control mode to CONTROL MODE SETPOINT
(for example control mode is interlock or fatal error)
2
ZERO DISABLED
Using zero function not possible
3
PFO DEACTIVATED
Power Failure Option is deactivated
4
NOT USED (reserved)
-
5
OUT OF RANGE:
PRESSURE SETPOINT
Value of PRESSURE SETPOINT is out of range
6
OUT OF RANGE:
POSITION SETPOINT
Value of POSITION SETPOINT is out of range
7-9
NOT USED (reserved)
-
10
OUT OF RANGE:
CONTROL MODE
SETPOINT
Value of CONTROL MODE SETPOINT is out of range
11
OUT OF RANGE:
GENERAL CONTROL
SETPOINT
Value of GENERAL CONTROL SETPOINT is out of range
12
PROCESS DATA
SETTING(S) NOT VALID
Value of PROCESS DATA SETTING(S) not valid
(DATA TYPE or RANGE of pressure and position signals)
13-15
NOT USED (reserved)
-