Installation, Operating & Maintenance Instructions
Series 650 DN 350 (I.D. 14”), CC-Link
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
286241EA
2010-10-11
64/86
Signal
Type
Name
Start
Word
Byte
Length
Data
Type
Valid
Range
Description
Bitmap
GENERAL STATUS
16
2
boolean
array
See bitmap table below
Bitmap
GENERAL WARNING
17
2
boolean
array
See bitmap table below
Bitmap
EXTENDED WARNING
18
2
boolean
array
See bitmap table below
Signal
CLUSTER VALVE
MONITORING
ADDRESS
19 1
unsigned
integer
0…254
Actual address of the selected cluster
valve.
Signal
CLUSTER VALVE
POSITION
20 4
signed
integer
(default) or
floating point
0…100’000
(default),
adjustable
1)
Actual position of the selected cluster
valve.
Signal
CLUSTER VALVE
CONTROL MODE
22 1
unsigned
integer
0…14
0 = init
1 = synch
2 = position
3 = close
4 = open
5 = pressure
6 = hold
7 = learn
8 = interlock open
9 = interlock close
10 = maintenance open
11 = maintenance close
12 = power failure
13 = safety
14 = fatal error
Bitmap
CLUSTER VALVE
STATUS
23
2
boolean
array
See bitmap table below
Bitmap
CLUSTER VALVE
WARNINGS
24
1
boolean
array
See bitmap table below
1) To adjust range refer to chapter: «Range of pressure and position values»