CLUSTER VALVE STATUS bitmap table:
This bitmap corresponds to the CLUSTER VALVE MONITORING ADDRESS.
Bit
Description
0-1
ACCESS MODE
bit 1
bit 0
0 0
= LOCAL
0 1
= REMOTE
1 0
= LOCKED
2
FREEZE MODE
Valve is in freeze mode (the slave valve is separated from the cluster)
3
OFFLINE STATUS
No communication with cluster valve
4-7
NOT USED (reserved)
-
8
SERVICE REQUEST
Valve movement tight
9
COMPRESSED AIR
Compressed air pressure < 4 bar (only for valves with compressed air)
10
POWER FAILURE
BATTERY
Not ready, voltage too low
11-15
NOT USED (reserved)
-
CLUSTER VALVE WARNINGS bitmap table:
Bit
Description
0
OUT OF RANGE:
CLUSTER VALVE
FREEZE POSITION
SETPOINT
Value of CLUSTER VALVE FREEZE POSITION SETPOINT is out of range
1
OUT OF RANGE:
CLUSTER VALVE
FREEZE ADDRESS
SETPOINT
Value of CLUSTER VALVE FREEZE ADDRESS SETPOINT is out of range
2
OUT OF RANGE:
CLUSTER VALVE
CONTROL SETPOINT
Value of CLUSTER VALVE CONTROL SETPOINT is out of range
3
OUT OF RANGE:
CLUSTER VALVE
MONITORING ADDRESS
SETPOINT
Value of CLUSTER VALVE MONITORING ADDRESS SETPOINT is out of range
4-7
NOT USED (reserved)
-