Ver
sion:
M
P4/
6 G
3
08/
01
/2024
30
3.3.
After installation
3.3.1.
Registration
Fill out the enclosed registration form. Post the copy with the pre-printed address
to Värmebaronen and give the other copy to the user.
3.3.2.
Installation engineer’s checklist
Before starting up the boiler
Has the electrical installation been adapted to the local power supply?
Are the boiler and heating system filled with water and vented?
Is the pressure correct?
Are all pipe connections leakproof?
Are the valves set to the correct position?
Has the bypass valve been adjusted?
Is the vent valve open so that the air can escape?
After starting up the boiler
Check that the circulation pump is correctly adjusted (see setting options in the
enclosed manual for the circulation pump) and is working properly.
Check that the outdoor sensor displays the correct temperature if an outdoor sensor is
installed.
Check that the room unit displays the correct temperature if an outdoor sensor
is installed.
Fill out the installation information on page 4 of the User Manual.
Demonstrate the boiler to the customer in accordance with Customer
demonstration/handover on page 32.
Fill out and post the installation registration to register the boiler and the warranty.
3.3.3.
Customer demonstration/handover
Demonstrate the parts and functions of the boiler to the user, and show where the information can be
found in the User Manual.
-
Demonstrate how the user should perform boiler maintenance (pages 13-15 of the User
Manual).
-
Demonstrate how the user should fill the system with water via the filling valve.
-
Explain the home screen on the display (page 8 of the User Manual).
-
Demonstrate how the user can increase and decrease the heating curve level (pages
10-11 of the User Manual).
-
Explain the ECO function to the user and demonstrate how the user activates and
deactivates the ECO function (page 10 of the User Manual).
-
Demonstrate how the user should set the time and date.
-
Explain alarms, warnings and limitations to the user (pages 12-13 of the User Manual).
-
Demonstrate how the user acknowledges an alarm or warning (page 17 of the User
Manual).
-