Ver
sion:
M
P4/
6 G
3
08/
01
/2024
11
If you are unhappy with the indoor temperature after adjusting the heating curve level, you can also
adjust the heating curve’s slope.
Adjust the heating curve slope
1. Press the menu button.
2. The heating curve is selected.
3. Press the Confirm button.
4. Use the right arrows to select the Heating curve slope icon.
-
Heating curve slope – can be adjusted between 21 and 60.
5. Confirm.
6.
Increase or decrease the value using the plus and minus buttons.
7. Confirm.
9. Press Return to go back to the menu.
2.4.5.
Safety functions
Level sensor
If the water level in the boiler decreases, the level sensor temporarily turns off the boiler
and triggers a warning.
If the level sensor has turned off the boiler, do not start the boiler again,
rather contact your installation engineer for troubleshooting and remedial
actions.
Over-temperature protection
The over-temperature protection is a digital safety feature. The boiler activates the
over-temperature protection before the mechanical overheating protection is triggered.
If the over-temperature protection is activated, you can reset the warning
yourself. Read about how to reset warnings on page 17. If the over-
temperature protection is triggered repeatedly, you must contact your
installation engineer for troubleshooting and remedial actions.
Overheating protection
The overheating protection is a mechanical safety feature that is triggered if the boiler temperature
exceeds 80°C.
If the overheating protection is triggered, you will need to reset it manually.
If the overheating protection is triggered repeatedly, contact your