2.6.

 

Troubleshooting 

 

Notify any error code when you contact your installation engineer. 

 

What has happened? 

What does it mean? 

What should I do? 

A warning signal sounds.  The boiler has activated 

an alarm.  

Turn off the alarm signal by acknowledging the 

alarm: 

1.

 

Press the button furthest  

to the left. 

2.

 

Press the button second-furthest to 

the left.  

3.

 

Check the alarm code shown on the display. 

4.

 

Contact your installation engineer for 

troubleshooting and remedial actions. 

Green indicator light  

is on. 

The boiler is working 

normally. 

No action is required. 

Yellow indicator light 

flashes. 

The boiler has activated 

a warning. If the cause of 

the condition ceases, the 

boiler will start up again, 

but the warning will 

remain on the display 

until you have 

acknowledged the 

warning. 

Make a note of the warning issued by the boiler.  

Acknowledge the warning.  

If the boiler does not start again, contact your 

installation engineer and notify them of the error 

code indicated by the boiler for troubleshooting 

and remedial actions.  

Read more about acknowledging warnings on page 

17. 

Yellow indicator light is 

on. 

You have acknowledged 

the warning, but the fault 

persists. 

If the light does not turn off within 24 hours or the 

warning is repeated, contact your installation 

engineer for troubleshooting and remedial actions.  

Red indicator light 

flashes. 

The boiler has activated 

an alarm and turned itself 

off. 

Make a note of the alarm issued by the boiler. 

Acknowledge the alarm. The boiler turns off the 

alarm signal. 
Contact your installation engineer for troubleshootin  

and remedial actions.  
Notify the installation engineer of the error code 

indicated by the boiler. Read more about 

acknowledging alarms on page 17. 

Red indicator light  

is on. 

The boiler has activated 

an alarm and turned itself 

off. You have 

acknowledged the alarm.  

Contact your installation engineer for 

troubleshooting and remedial actions. Notify the 

installation engineer of the error code indicated by 

the boiler. 

The boiler does  

not start. 

The boiler has stopped 

because it has triggered 

an alarm or warning. 

Check the indicator lights and see above. 

Refer to page 6 for the location of the indicator 

lights on the control panel. 

The display shows  

a warning bell with  

a white background.  

 

The boiler has activated 

a limitation.  

No action is required. 

Press the button below the warning bell to see 

which limitation has been activated. 

The display shows  

a triangle and the 

warning bell with  

a black background. 

The boiler has activated 

an alarm  

or a warning. 

Check the indicator lights and see above. 

Refer to page 6 for the location of the indicator 

lights on the control panel. 

Summary of Contents for MP4 G3

Page 1: ...Mini Boiler MP4 G3 and MP6 G3 MANUAL Use and Installation...

Page 2: ...1 2 4 6 Alarms warnings and limitations 12 2 5 Maintenance 13 2 6 Troubleshooting 16 3 Installation Manual 18 3 1 Safety 18 3 2 Installation 18 3 2 1 Installation overview 18 3 2 2 Preparations 18 3 2...

Page 3: ...you will find technical information as well as instructions relating to installation and service NOTE Installation and service may only be carried out by a qualified installation engineer 1 3 Explanat...

Page 4: ...ibed on pages 13 16 Always contact your installation engineer for service The boiler is not permitted to be modified changed or converted in any way Never place any combustible material on the boiler...

Page 5: ...set to 1 5 bar YES to bar The water pressure must not be below the pre charge pressure 0 2 bar Example If the pre charge pressure has been adjusted to 1 6 bar the water pressure must be between 1 8 an...

Page 6: ...Version MP4 6 G3 08 01 2024 5 2 3 Overview...

Page 7: ...the boiler s electronics from being splashed with water 1 Control panel 2 Power switch 3 Overheating protection 4 Vent valve 5 Safety valve 6 Pressure gauge 7 Drain water tank 8 Expansion tank 9 Circ...

Page 8: ...u you have selected Cover 15 The cover protects the boiler from contaminants The cover must always be mounted on the boiler except during maintenance and when changing settings Locking mechanism 16 Th...

Page 9: ...r temperature exceeds 80 C If the overheating protection is triggered you will need to reset it manually Read more about resetting the overheating protection on page 12 2 4 Functions and settings Do n...

Page 10: ...o the home screen Basic settings The installation engineer sets the language time and date at the time of installation In the event of a power cut lasting longer than 3 4 days you or the installation...

Page 11: ...to the outdoor temperature The installation engineer sets a heating curve that is adapted to the heating surface s insulation and the design of the heating system If you have installed a room unit the...

Page 12: ...start the boiler again rather contact your installation engineer for troubleshooting and remedial actions Over temperature protection The over temperature protection is a digital safety feature The b...

Page 13: ...nd contact your installation engineer for troubleshooting and remedial actions Anti freeze If the boiler or system is in a low temperature environment the installation engineer can add anti freeze and...

Page 14: ...ted Activity log The boiler saves operational information in an activity log The installation engineer can use this information for troubleshooting and to make adjustments 2 5 Maintenance In order for...

Page 15: ...ystem does not lose too much water and pressure The water pressure should be checked when the boiler is cold For every quarter of a turn anticlockwise a popping sound can be heard 8 Open and close the...

Page 16: ...ng valve is missing contact your installation engineer If you would like help adjusting the water pressure please contact your installation engineer Empty the drain water tank 12 Remove the drain wate...

Page 17: ...s or the warning is repeated contact your installation engineer for troubleshooting and remedial actions Red indicator light flashes The boiler has activated an alarm and turned itself off Make a note...

Page 18: ...protection or contact your installation engineer Read how to reset the overheating protection on page 12 Acknowledging an alarm warning or limitation 1 Press the button furthest to the left 2 Press th...

Page 19: ...not included in the boiler delivery 2 Install the boiler 3 Install the pipe system 4 Fill with water 5 Install the electricity 6 Test the boiler in accordance with the Installation engineer s checkli...

Page 20: ...oiler so that the immersion heater can be replaced if necessary Install the outdoor sensor Connect the outdoor sensor to the boiler using a cable with a cross section of at least 0 5 mm2 and a maximum...

Page 21: ...ures Pipe system Shut off throttle valves Filling and drain valve Flow direction Water source 3 2 5 Fill with water and adjust the pressure Always check that the expansion tank has sufficient volume C...

Page 22: ...has a capacity of 2 litres and the preset pre charge pressure is 1 5 bar It can handle a system volume of 70 litres at 60 C and 5 metres of static pressure Adjust the bypass valve To safeguard the fl...

Page 23: ...ump 4 Overheating protection 5 Control switch 6 Cable between panel and power board 7 Boiler temperature sensor 8 Connection for outdoor temperature sensor 9 Connection external blocking alternative t...

Page 24: ...ation to electrical installation may only be carried out by qualified personnel For an explanation of labels see page 22 Jumper N X option for single phase coupling and for increasing the power in the...

Page 25: ...e protection 10 A Jumper N X Two phases without jumper MP4 2 25 kW 400 V 2N 5 6 A MP6 3 0 kW 400 V 2N 7 5 A Power cable 4 x 1 5 mm2 Fuse protection 2 x 10 A Two phases with jumper MP4 3 0 kW 400 V 2N...

Page 26: ...to refit the red cap to ensure that the vent valve works automatically The float switch temporarily turns off the boiler and triggers a warning if the vent valve is unable to vent the boiler automatic...

Page 27: ...Version MP4 6 G3 08 01 2024 26 Menu overview...

Page 28: ...ation is activated you can test operate the circulation pump manually Select 1 to start the circulation pump and 0 to stop the circulation pump ECO function Main menu The ECO function must be switched...

Page 29: ...ly deactivated after four minutes of inactivity Manual operation Installation engineer settings Advanced Manual operation is used to test the boiler s functions manually Max flow Installation engineer...

Page 30: ...low buzzer Installation engineer settings Advanced Select ON to activate the alarm signal and select OFF to deactivate the alarm signal The factory setting is ON USB Installation engineer settings Adv...

Page 31: ...tion information on page 4 of the User Manual Demonstrate the boiler to the customer in accordance with Customer demonstration handover on page 32 Fill out and post the installation registration to re...

Page 32: ...uses and that the boiler s control switch is in the on position The group fuses for the boiler are triggered The immersion heater is broken Check by checking the insulation of the immersion heater Mea...

Page 33: ...h boiler temp Warning The over temperature protection has temporarily stopped the boiler from heating When the boiler temperature has dropped by 5 C regulation will be resumed W03 Low boiler temp Warn...

Page 34: ...f or is rectified Information about the alarm remains in the log list Warning When the boiler activates a warning the yellow indicator light flashes When the user or installation engineer has acknowle...

Page 35: ...230 V 400 V 400 V 400 V Frequency 50 60 50 60 50 60 50 60 Current 6 5 A 5 6 A 7 5 A 6 5 A Fuse protectio 10 A 2 x 10 2 x 10 3 x 10 MP6 G3 Power options 2 0 kW 3 0 kW 4 0 kW 6 0 kW Voltage 230 V 400 V...

Page 36: ...246221 Expansion tank 1 245117 H bypass bypass valve 1 280018 Insulation immersion heater container 1 210224 Cable power panel circuit board 1 210234 Power circuit board 1 720259 Cover 1 380051 Pressu...

Reviews: