61
Troubleshooting
Error Messages
If a problem occurs during luminaire calibration, at the end of the calibration sequence the
Menu Display will cycle through any applicable error message(s) until the end of the list is
reached. To review the error messages again, it will be necessary to access them using the
Status function.
To access error messages:
Step
1.
Press
.
Step 2. Press
arrows until Fixture appears. Press
.
Step 3. Press
arrows to access Status. Press
. (Display will now scroll
through any error messages or display OK if no errors.)
Table A-1: Error Messages
Display
Message
No Errors
Fixture is ok
NO Sensor On Pan
Pan sensor not found, Pan ReCalibrate fail. Note:For safety, the lamp will shut off
automatically if there is a pan error on startup.
NO Sensor On Tilt
Tilt sensor not found, Tilt ReCalibrate fail. Note:For safety, the lamp will shut off
automatically if there is a tilt error on startup.
NO Sensor On Cyan
Cyan sensor not found, Cyan ReCalibrate fail.
NO Sensor On Magenta
Magenta sensor not found, Magenta ReCalibrate fail.
NO Sensor On Yellow
Yellow sensor not found, Yellow ReCalibrate fail.
NO Sensor On Color Wheel
Color Wheel sensor not found, Color Wheel1 ReCalibrate fail.
NO Sensor On Rot Gobo1
Rotating Gobo1 sensor not found, Rotating Gobo1 ReCalibrate fail.
NO Sensor On Rot Gobo2
Rotating Gobo2 sensor not found, Rotating Gobo2 ReCalibrate fail.
NO Sensor On Gobo 2 Rot
Rotating Gobo2 Indexing sensor not found,Rotating Gobo2 Indexing ReCalibrate fail.
NO Sensor On Rot Gobo3
Rotating Gobo3 sensor not found, Rotating Gobo3 ReCalibrate fail.
NO Sensor On Gobo3 Rot
Rotating Gobo3 Indexing sensor not found, Rotating Gobo3 Indexing ReCalibrate fail.
NO Sensor On Prism
Prism sensor not found, Prism ReCalibrate fail.
NO Sensor On Prism_R
Prism Rotate sensor not found, Prism Rotate ReCalibrate fail.
NO Sensor On Prism 2
Prism 2 sensor not found, Prism 2 ReCalibrate fail.
NO Sensor On Prism 2_R
Prism 2 Rotate sensor not found, Prism 2 Rotate ReCalibrate fail.
NO Sensor On Focus
Focus sensor not found, Focus ReCalibrate fail.
NO Sensor On Zoom
Zoom sensor not found, Zoom ReCalibrate fail.
NO Sensor On Frost 1
Frost1 sensor not found, Frost1 ReCalibrate fail.
NO Sensor On Frost 2
Frost2 sensor not found, Frost2 ReCalibrate fail.
NO Sensor On Flow
Flow sensor not found, Flow ReCalibrate fail.
NO Sensor On Intensity
Intensity sensor not found, Intensity ReCalibrate fail.
Ballast_Fault_1
Lamp over voltage(01h)
Ballast_Fault_2
Input voltage too high(02h)
Ballast_Fault_3
Temperature too high(03h)
Ballast_Fault_4
Asymmetry detected(04h)
Ballast_Fault_5
Lamp under voltage(05h)
Ballast_Fault_6
Input voltage too low(06h)
Ballast_Fault_8
NTC defective(08h)
Ballast_Fault_Other
Ballast other fault(0Ah)
Ballast Over Temp
Temperature too high(03h)(same Ballast_Fault_3)
Fan Fault
Fan Fault
Accelerometer Err
Accelerometer Err
Shift Fan Fault
Shift Fan Fault
VARI
LITE VL10 BeamWash User’s Manual
Summary of Contents for VL10 BeamWash
Page 1: ...VARll lllllE USER1 S MANUAL...
Page 21: ...7 Notes DESCRIPTION COMPONENTS 1...
Page 27: ...13 Figure 2 3 Installing Brackets on Luminaire Enclosure VARI LITE VL10 BeamWash User s Manual...
Page 64: ...50 Notes VARI LITE VL10 BeamWash User s Manual...
Page 71: ...57 Notes VARI LITE VL10 BeamWash User s Manual...
Page 83: ...69 Dimensions...
Page 84: ...70...