Power and Data Cabling Requirements
Power
The luminaire requires standard AC power distribution from AC100-240V~, 50/60Hz.
Current required depends on the AC supply voltage and product model.
Note: The mating Neutrik PowerCon connector is supplied, however, you will need to
purchase or construct a cable appropriate for your application.
Allow one hour warm up if ambient temperature is below 10
50
.
Figure 2-1: Power Connector
Depending on the application, the luminaire’s AC input cable may require a different
connector. If required, install a new connector meeting your requirements using the
following wire color code reference:
Wire*
Connection
Green
AC Ground
White
AC Neutral
Black
AC Line
* International (Harmonized) Standard
WARNING: DO NOT connect to three-phase service in countries with 240 volt power.
AVERTISSEMENT: NE PAS se connecter au service en trois phases dans les pays avec
puissance de 240 volts.