2920 Float & Tape Transmitter
10 Configuring HART Devices
118
Installation and Operations Manual
Verifying Communications with a Temperature Device
Do the following to verify communications with a Varec or E+H multi-element temperature
device:
1. Press Enter to open the Main Menu.
2. Press Minus multiple times to select the NMT Prothermo menu.
3. Press Enter to open the NMT Prothermo menu.
4. Press Enter to open the Display Only menu.
5. Press Minus 2 times to locate the Pnt Status.
Verifying Communications with a Level Device
Do the following to verify communications with a Varec or E+H RADAR device:
1. Press Enter to open the Main Menu.
2. Press Minus multiple times to select the FMR Radar menu.
3. Press Enter to open the FMR Radar menu.
4. Press Enter to open the Display Only menu.
5. Press Minus 2 times to locate the Pnt Status.
Verifying Communications with a Generic HART Device
Do the following to verify communications with a generic HART device:
1. Press Enter to open the Main Menu.
2. Press Minus multiple times to select the HART Device menu.
3. Press Enter to open the HART Device menu.
4. Select one of the HART Device #s.
5. Press Enter to open the HART Device # menu.
6. Press Minus 2 times to locate the Pnt Status.
If the Pnt Status is...
Then Communications are...
0000
Online
0x01
Offline
If the Pnt Status is...
Then Communications are...
0000
Online
0x01
Offline
If the Pnt Status is...
Then Communications are...
0000
Online
0x01
Offline
Summary of Contents for 2920
Page 2: ......
Page 16: ...2920 Float Tape Transmitter 1 Introduction 6 Installation and Operations Manual...
Page 114: ...2920 Float Tape Transmitter 6 Bi Phase Mark 104 Installation and Operations Manual...
Page 120: ...2920 Float Tape Transmitter 7 MODBUS 110 Installation and Operations Manual...
Page 126: ...2920 Float Tape Transmitter 9 L J TankWay 116 Installation and Operations Manual...
Page 158: ...2920 Float Tape Transmitter 14 Ordering Information 148 Installation and Operations Manual...
Page 193: ......