6 Bi-Phase Mark
Varec, Inc.
103
To Set the 2920 FTT Gauge Type
1. Follow steps 1 through 5 in the 2920 FTT unit address procedure (above).
2. In the Config Params menu, select Gauge Type.
3. Press Enter to modify the Gauge Type parameter.
4. Press Minus or Plus to select English or Metric for the gauge type.
5. Continue following steps 9 through 12 above to complete the baud rate setup.
To Set the 2920 FTT Encoder Direction
1. Follow steps 1 through 5 in the 2920 FTT unit address procedure (above).
2. In the Config Params menu, select Enc Direction.
3. Press Enter to modify the Enc Direction parameter.
4. Press Minus or Plus to select Forward or Reverse for the encoder direction for this device.
5. Continue following steps 9 through 12 above to complete the baud rate setup.
To Set the RTD Type
1. Follow steps 1 through 5 in the 2920 FTT unit address procedure (above).
2. In the Config Params menu, select RTD Type.
3. Press Enter to modify the RTD Type parameter.
4. Press Minus or Plus to select one of the following for the RTD Type for this device.
• Pt100 – Platinum 100 RTD
• Cu100 – Copper 100 RTD
• Cu90 – Copper 90 RTD
5. Continue following steps 9 through 12 above to complete the baud rate setup.
Summary of Contents for 2920
Page 2: ......
Page 16: ...2920 Float Tape Transmitter 1 Introduction 6 Installation and Operations Manual...
Page 114: ...2920 Float Tape Transmitter 6 Bi Phase Mark 104 Installation and Operations Manual...
Page 120: ...2920 Float Tape Transmitter 7 MODBUS 110 Installation and Operations Manual...
Page 126: ...2920 Float Tape Transmitter 9 L J TankWay 116 Installation and Operations Manual...
Page 158: ...2920 Float Tape Transmitter 14 Ordering Information 148 Installation and Operations Manual...
Page 193: ......