E5
−
H High Performance Universal Inverter User Manual
34
Chapter 4 Using Instructions of Operation Panel
4.7 Operation Panel Display and Key Operation
4.7.1 Classification of Display Status
There are 8 types of display status of operation panel:
SN
Status
Meaning
1
Display status of stopping
parameters
Press >> key to switch the displayed parameters, P2.03 can be used
to set the displayed parameters.
2
Display status of running
parameters
Press >> key to switch the displayed parameters, P2.02 can be used
to set the displayed parameters.
3
Display status of fault and
alarm
In other 7 kinds of display status, if there is any fault happens,
directly enter this status.
4
Display status of first level
menu
When the keys are not locked, in status of SN1, SN2, SN3 and SN7,
press PRG to enter.
5
Display status of second
level menu
In the display status of first level menu, press PRG to enter.
6 Password
verification
status
If password protection is enabled, press PRG to enter in the display
status of first level menu.
7
Password modification
status
In the display status of stopping and running parameters, press
∧
and
∨
to enter.
8
Information prompt status
See 4.4.5 for identifying the LED display characters.
4.7.2 Display Status and Operation Process
>> key
In the display status of first level menu, press >> key to select the edit bit of function code PX.YZ.
In second level menu or password verification status, press >> key to select the data edit bit.
Auto switch between status
If no key is pressed for 30s, the screen automatically returns to the display status of stopping
parameters, or the display status of running parameters.
If no key is pressed for 1 minute, clear menu edit status of PX.YZ to return to P0.00.
If there is password setting or key locking setting and if no key is pressed for 5 minutes, the panel will
enter password protection or locking status automatically.