E5
−
H High Performance Universal Inverter User Manual
Chapter 1 Introduction to E5
−
H Series Inverter
3
1.4 Technical Specifications of Product
Control mode
Process open loop control
Startup torque
0.50Hz 180%
Speed adjustment range
1:100
Control
features
Speed stabilization
precision
± 0.5%
Key functions
Undervoltage adjustment, switching of AC operation grounding, protective
grounding and DC operation grounding, rotation speed tracing, torque
limitation, multi
−
speed operation (up to 16 speeds), auto
−
tuning, S curve
acceleration/deceleration, slip compensation, PID regulation, current limiting
control, manual/auto torque increase, current limiting.
Frequency setting mode
Frequency can be set via operation panel, UP/DN terminal, or analog inputs
of AI1 and AI2, and can also be set through communication with host
computer,
Frequency range
0.00 ~ 300.00Hz
Startup frequency
0.00~60.00Hz
Acceleration/deceleration
time
0.1~36000s
Powered braking
capacity
Braking unit action voltage: 650 ~ 750V
DC braking capacity
DC braking initial frequency: 0.00 ~ 300.0Hz; DC braking current: Constant
torque: 0.0 ~ 120.0%, Variable torque: 0. 0 ~ 90.0%
DC braking time: 0.0 ~ 30.0s; there is no initial waiting time for the DC braking
to realize quick braking
Product
functions
Magnetic flux braking
function
Ongoing action and no action upon deceleration as option, no action upon
deceleration at default
Multifunctional M key
The unique multifunctional key is used to set the frequently used operations:
JOG, emergent stop, Running command issuing mode switch , menu
switching
Multiple menu modes
Basic menu mode, fast menu mode.
Menu mode of non
−
factory setting
function codes, Menu mode of last changed 10 function codes
Parameter copy
The standard operation panel can realize the parameter upload, download
and display the copy progress. User can select to forbid the overwriting of the
uploaded parameters.
Displayed/hidden
function code
The customer can select to display or hide the function codes byhimself.
Dual RS485
communication ports
Support Modbus protocol (RTU). The standard operation panel can realize
the function of remote control box with a maximum distance of 500m.
Operation panel
Button type or shuttle type operation panel optional, protection class: IP20 as
standard, IP54 as option
Shared DC bus
The full series can realize shared DC bus supply for several inverters.
Independent duct
The full series adopts independent duct design and supports the installation
of heatsink outside the cabinet
Unique
functions
Power
−
up
auto
−
detection
Realizing the power
−
up auto
−
detection of internal and peripheral circuits,
including motor grounding, ab10V power supply output, abnormal