E5
−
H High Performance Universal Inverter User Manual
124
Appendix B Control Mode Setting Process
Appendix B Control Mode Setting Process
1. Setting Process for Auto
−
tuning
Parameter auto
−
tuning under V/F control
START
Setting P0.01=5
Setting rated voltage of motor
P0.12
Setting rated frequency of motor
P0.15
Setting upper frequency limit of motor
P0.13
Setting max frequency of motor
P0.11
Setting motor parameter
(
P9.00 P9.04
)
Setting P9.15=1
Press RUN key to perform
parameter tuning
END
Motor with multi V/F
Setting P4.00=1
,
auto torque boost
invalid
,
please
setting about
P0.16=3% manual
torque boost
Motor with multi power V/F
Please select correct P4.00to
2 6 according to upon
variable torque load
Setting correct
P4.01 P4.08
N
Y
Y
N