E5
−
H High Performance Universal Inverter User Manual
68 Chapter
6
Parameter
Description
disabled.
Note: During open loop operation process, if the input terminal function sets the multi
−
section digital
voltage and multi
−
section frequency simultaneously, the multi
−
section frequency has the highest priority.
Multi
−
section
frequency
terminal 1
Multi
−
section
frequency
terminal 3
Multi
−
section
frequency
terminal 2
Multi
−
section
frequency
terminal 1
Setting frequency
OFF OFF OFF OFF
Open loop frequency
P0.05
OFF OFF OFF
ON
Multi
−
section
frequency 1
OFF OFF ON
OFF
Multi
−
section
frequency 2
OFF OFF ON
ON
Multi
−
section
frequency 3
OFF ON OFF OFF
Multi
−
section
frequency 4
OFF ON OFF ON
Multi
−
section
frequency 5
OFF ON ON OFF
Multi
−
section
frequency 6
OFF ON ON
ON
Multi
−
section
frequency 7
ON OFF OFF OFF
Multi
−
section
frequency 8
ON OFF OFF ON
Multi
−
section
frequency 9
ON OFF ON OFF
Multi
−
section
frequency 10
ON OFF ON
ON
Multi
−
section
frequency 11
ON ON OFF OFF
Multi
−
section
frequency 12
ON ON OFF ON
Multi
−
section
frequency 13
ON ON ON OFF
Multi
−
section
frequency 14
ON ON ON ON
Multi
−
section
frequency 15
6.6 Multi
−
functional Input Parameter (Group P5)
P5.00
X1 terminal input function selection
0~99(99)
P5.01
X2 terminal input function selection
0~99(99)
P5.02
X3 terminal input function selection
0~99(99)
P5.03
X4 terminal input function selection
0~99(99)