V-301G Series Operating Instructions Ver. 2.01E
33
Control panel setting
Ŷ
Manual vacuuming· timer gas-flushing / manual vacuuming· timer gas-flushing & seal
Operation Procedures
Reference
1
Set a heating timer from 1 to 10 depending on the required heat time.
8-6-1 Setting the heating timer
2
Select the operation mode 2.
8-6-2 Selecting operation mode
3
Set a vacuum timer to the MANUAL position.
6HWWLQJWKHYDFXXPDQGJDVÀXVK
timers
4
Set a gas timer from 1 to 9 depending on the required vacuum level.
6HWWLQJWKHYDFXXPDQGJDVÀXVK
timers
5
Move a nozzle forward by pressing a START/STOP button.
8-7 Forward a nozzle
6
Place a pouch to the seal area.
8-8 Place a pouch to the seal area
7
Push down on a table to the intermediate position.
8-9 Press down a table
8
Push a START/STOP button to start vacuuming.
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
9
When optimum vacuum level is achieved, push a START/STOP button to
VWRSYDFXXPLQJ7KH¿UVWJDVÀXVKLQJZLOOVWDUWDQG¿QLVKHVJDVÀXVKLQJDIWHU
passing the set time.
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
10
Push a START/STOP button to stop vacuuming at optimum timing. Vacuuming
VWRSVDQGWKHVHFRQGJDVÀXVKLQJZLOOVWDUW*DVÀXVKLQJVWRSVDXWRPDWLFDOO\
after passing the set time and a nozzle will withdraw to the back position.
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
11
After nozzle withdrawal, press down on a table further down to perform
sealing.
8-11 Press a table further down to seal
12
7DNHVXI¿FLHQWFRROLQJWLPH
7DNHVXI¿FLHQWFRROLQJWLPH
13
Sealing is complete.
7KH¿QLVKHGVHDO
Heating timer dial: 1~10
Mode selection switch: 2
Gas timer dial : 1~9
Vacuum timer dial: MANUAL