14
V-301G Series Operating Instructions Ver. 2.01E
Use only as described in this manual.
There is a risk of danger and malfunctions may result if the machine is used not in accordance with this manual.
This machine is a desk type sealer. Place the machine on a
flat, horizontal surface and secure an appropriate
workbench.
1
Remove the plastic nuts (white) and insert the
screws of the table into the designated holes.
2
Fasten the plastic nuts (white) to fix the table
securely.
Please prepare for the regulators to regulate the gas flow
by the user. It is not included in the V-301G series.
1
Install the regulators that has the reducing valve
and flowmeter to the gas cylinder.
2
The gas cock for providing the gas is located on
the right side of the machine. Install the rubber
tube
3
Adjust he gas regulators according to the bag
size.
・
Specified flow rate
=
25 l/min
・
Standard pressure
=
0.15 MPa
8 Proper use of the sealer
8-1 Securing the machine
8-2 Table attachment
8-3 How to connect a gas-cylinder to
V-301G series
Plastic nut (white)
Holder
Coupler
Hose band
Gas cock
Warning
Installing the machine on an unstable or
inclined surface may cause the overturn of
the sealer.
TIPS
The coupler size is diameter 9mm.
TIPS
About the gas flushing timer, please
refer to “8-6 Seal parameter
settings >>>8-6-3 Setting the
vacuum and gas-flush timers.”