V-301G Series Operating Instructions Ver. 2.01E
13
■
The illustaion of V-301G
7 Major parts and function
Control Panel
START/STOP button
When the lever is open, the
nozzle moves back and forth by
pressing this button.
When the manual [=continuous]
mode is selected, the vacuuming
or gas-flushing starts/stops by
pressing this botton.
Mode selection switch
You can swith the
operation mode from:
1
= 1 cycle of vacuuming
and gas-flushing.
2
= 2 cycles of
vacuuming and gas-
flushing.
Air filter
Gas cock
Body cover
Power switch
Electrode
Push to turn ON the
power. Pushing it again
will turn OFF the power.
Control panel
Nozzle
Gas is inserted into the
bag through this nozzle.
Table
Depress the table to
seal.
Push the area indicated
in the label.
Sponge pad
Works as packing while
gas-flushing.
Power lamp
The light will turn ON
when the machine power
is ON.
Heat lamp
The light will turn ON
during the heating
process.
Gas lamp
The light will turn ON
during the gas-flushing
process.
Vacuum lamp
The light will turn ON
during the vacuuming
process.
Heating timer dial
Adjust the heat timer
according to the
thickness of the bag
thickness and material.
(0.1 ~ 2.3 seconds)
Gas timer dial
Adjust the gas timer according to
the bag size and packaging
content. (Dial 1~9= about 0.1~20
seconds, or manual[=continuous]
mode)
Vacuum timer dial
Adjust the vacuum timer
according to the bag size and
packaging content. (Dial 1~9=
about 0.1~20 seconds, or
manual[=continuous] mode)