16
V-301G Series Operating Instructions Ver. 2.01E
Reference time for vacuuming and gas-flushing dials
Scale
1
2
3
4
5
6
7
8
9
Vac/Gas Time (sec)
0.5
2.5
5
7.5
10.5
13
16
18
19
By turning the mode selection switch, you can switch
the operation mode between the followings.
Mode 1: perform one cycle of vacuuming and gas-
flushing.
Mode 2: perform two cycles of vacuuming and gas-
flushing.
Set a vacuum and gas-flushing timers by turning the
respective dials. The bigger the scale number is, the
longer the heat time will be.
[Dial 1 ~ 9 = about 0.1 ~ 20 seconds/ Manual =
continuous operation mode.]
8-6-2 Selecting operation mode
8-6-3 Setting the vacuum and gas-flush
timers
Mode selection switch
Gas timer dial
Vacuum timer dial
Attention
When you set a vacuum or gas-flushing
timer to the manual mode, you will hear a
one brief beep. (Also you will hear two
beeps when you cancel a manual mode.)
Under the manual mode, the vacuuming or
gas-flushing operation continues until you
press a START/STOP button.
TIPS
For the detail of each operation mode,
please refer to “9 Mode setting and