Valloy Incorporation.
Any-002
User Manual
any-002
© 2015 Valloy Inc. All rights reserved.
Rev 1.0
– 2015.10
60 of 68
144: Error ~
147: Error
Error
The locking lever of the
new toner does not
lock.
(144=Y, 145=M,
146=C, 147=K)
installed?
Is the Toner Locking Lever
Error Message displayed?
Does the error occur after
replacing the ID?
Yes
Yes
No
Set up the locking lever again.
Replace the Toner Supply Unit.
Replace the ID.
SERVICE CALL
150: Error ~
153: Error
The fuse of the Drum
does not blow.
(150=Y, 151=M,
152=C, 153=K)
Is the Drum correctly
installed?
Does the error occur again?
Is the error corrected after
replacing the PRT board?
No
Yes
Yes
No
Reinstall the Drum.
Turn on the power again.
Replace the PU board after
checking the cable.
Replace the PU board.
SERVICE CALL
154: Error
The fuse of the Transfer
Belt does not blow.
Is the Transfer Belt correctly
installed?
Does the error occur again?
No
Yes
Yes
Reinstall the Transfer Belt.
Turn on the power again.
Replace the PU board after
checking the cable.
SERVICE CALL
155: Error
The fuse of the Fuser
does not blow.
Is the fuser correctly
installed?
Does the error occur again?
No
Yes
Yes
Reinstalled the connector of the
fuser after cleaning.
Turn on the power again.
Replace the PU board after
checking the cable.
SERVICE CALL
160: Error ~
163: Error
Toner Sensor Detection
Defect
(160=Y, 161=M, 162=C,
163=K) It does not
occur under factory
default condition.
Is the Toner Cartridge
installed?
Is the fixing lever of the
Toner fixed?
Does the error occur again?
No
No
Yes
Turn the Fixing Lever of the Toner
which is used to install the Toner
Cartridge to the fixing position. .
Turn on the power again.
Replace the toner sensor.
SERVICE CALL
167: Error
Thermister Error
Is the error displayed?
Does the error occur again?
Yes
Yes
Turn on the power again.
Turn on the power again after
leaving the unit for 30 minutes.
SERVICE CALL
168: Error
Compensation (Serve)
Thermister Error
Is the error displayed?
Is the error displayed?
Yes
Yes
Turn on the power again.
Turn on the power again after
leaving the unit for 30 minutes.
SERVICE CALL
169: Error
Top (Serve) Thermister
Error
Is the error displayed?
Does the error occur again?
Yes
Yes
Turn on the power again.
Turn on the power again after
leaving the unit for 30 minutes.
SERVICE CALL
170: Error
171: Error
Short circuit or
disconnection of the
Fuser Thermister
detected
Does the error occur again?
Yes
Turn on the power again after 30
minutes.
Replace the fuser.
SERVICE CALL
172: Error
173: Error
Temperature
abnormality (High or
Low Temperature) of
the Fuser Thermister
detected
Does the error occur again?
Yes
Turn on the power again after 30
minutes.
Replace the fuser.
Replace the LVPS.
SERVICE CALL
174: Error
Short circuit of the
Backup Roller
Thermister (High
Temperature) detected
Does the error occur again?
Yes
Turn on the power again after 30
minutes.
Replace the fuser.