of the Hurray
Thermister (908)
POWER OFF/ON
910: Error ~
914: Error
GDDC Error
910: Tray 1 GDDC Error
911: Tray 2 GDDC Error
912: Tray 3 GDDC Error
913: Tray 4 GDDC Error
914: Tray 5 GDDC Error
Check whether the Tray is correctly
installed.
Replace the Tray Motor.
POWER OFF/ON
917: Error
Belt Slit Sensor Error
Is the belt rotates normally?
Is the error displayed after
the power is turned OFF/ON?
Yes
Check the Belt installation state
and re-install it.
Replace the Belt.
SERVICE CALL
918: Error
Duplex Printing Device
Fan Caution Display
detected
Duplex Printing Device
internal fan error
Does the error occur when
the power is turned on
again?
Yes
Yes
Check whether the Duplex Printing
Device is normally installed.
Check whether the FAN is normally
installed.
Replace the fan.
POWER OFF/ON
923: Error
Image Drum Lock Error
Check whether the Drum
correctly operates.
Is the error displayed again
after turning the power?
Yes
Yes
Check whether the Drum is
correctly installed.
Replace the Drum.
Replace the Drum Motor.
SERVICE CALL
928: Error
Fuser Motor Lock Error
Does the fuser normally
operate?
Does the error occur again?
Yes
Yes
Check whether the Fuser is
correctly installed.
Replace the Fuser.
Replace the Fuser Motor.
POWER OFF/ON
919: Error
The 24 V power of the
Duplex Printing Device
is abnormal.
24 V power is not supplied to
the Duplex Printing Device.
Check whether the Duplex Printing
Device is correctly installed and
install it again.
Check the connector of the Duplex
Printing Device.
POWER OFF/ON
920: Y
921: M
922: C
923: K
Drum Lock Error
The relevant ID does not
rotate properly.
Is the error displayed after
the power is OFF/ON?
Yes
Check whether the relevant ID is
correctly installed and install it
again.
Replace the relevant ID.
Replace the relevant ID Motor.
SERVICE CALL
924: Tray 2
925: Tray 3
926: Tray 4
927: Tray 5
24 V power is not
supplied to each
relevant Tray.
24 V power is not properly
supplied to each relevant
Tray.
Check the installation state and the
connector of each Tray.
POWER OFF/ON
928: Error
Fuser Motor Lock Error
Dose the Fuser properly
rotate?
Check whether the Fuser is
correctly installed and install it
again.
Replace the Fuser.
Replace the Fuser Motor.
POWER OFF/ON
929:Error
Used Toner Return
Motor Lock Error
Check whether the Used
Toner Return Motor rotates
normally.
Check the Return Driving System of
the Used Toner and, if no problem
is found, replace the Used Toner
Motor.
POWER OFF/ON Relevant CPU Clock
The frequency of the relevant
Check the connection of the